Automatic Closing; Automatic Closure Operation; Activating Automatic Closing - SOMFY FREEVIA LINE Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.2 Automatic closing

Automatic closure operation

Press button 1 on the remote control to open the gate.
The gate closes again a er 30 seconds or 5 seconds if the photoelectric cells detect a passage.
The automatic closing can be interrupted by pressing button 1 on the remote control. To then close the
gate, press button 1 on the remote control again.

Activating automatic closing

The automatic closing can only be activated if the photoelectric cells are connected and recognised by
the motor's control electronics.
1
>2s
• Press on the
button of
the control electronics for 2
seconds.
The indicator light
on.
4
• Keep button 2 on the remote control depressed
until the indicator light
constantly.
2
• Place the remote control
against the control electronics.
comes
goes out and is then lit
Advanced parameter settings
3
• Keep button 1 of the remote
control depressed until the
indicator light
5
6
• When you release button
2, the indicator light
flashes; press button 1 on
the remote control 3 times
EN - FREEVIA LINE installation and operating guide - SOMFY
4
flashes.
7
x3
The indicator
light
remains lit.
Automatic
closing is
activated.
23

Publicité

Table des Matières
loading