Technical Data - SOMFY Elixo 500 3S RTS Manuel D'installation

Masquer les pouces Voir aussi pour Elixo 500 3S RTS:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elixo 500 3S RTS

12. TECHNICAL DATA

GENERAL SPECIFICATIONS
Power supply
Max. power consumption
Programming interface
Climatic operating conditions
Radio frequency
Number of memorisable channels
CONNECTIONS
Programmable safety
Type
input
Compatibility
Wired control input
Remote lighting output
Orange light output
Controlled 24 V power supply output
Safety input test output
Accessories power supply output
Offset aerial input
Backup battery input
Copyright © 2017 SOMFY ACTIVITES SA. All rights reserved.
230 V - 50/60 Hz
600 W (with 500 W remote
lighting)
7 buttons - 3-character LCD
screen
- 20°C/+ 60°C - IP 44
433.42 MHz
< 10 mW
40
Dry contact: NC
TX/RX photoelectric cells - Bus
cells - Reflex photocell - Dry
contact output safety edge
Dry contact: NO
230 V - 500 W (Halogen or incan-
descent only)
24 V - 15 W with integrated flash-
ing management
Yes: for possible TX/RX photoelec-
tric cells autotest
Yes: for possible autotest on reflex
cell or safety edge
24 V - 1.2 A max
Yes: compatible with RTS aerial
(ref. 2400472)
Yes: compatible 9.6 V battery
packs (ref. 9001001) and 24 V
battery packs (ref. 9016732)
Battery life: 24 hours; 5 to 10
cycles depending on the gate
Charging time: 48 hours
OPERATION
Forced operating mode
Independent remote lighting control
Timed lighting (a er movement)
Automatic closing mode
Orange light warning
When closing
Security entry
Before opening
operation
(ADMAP)
Partial opening control
Gradual starting
Opening speed
Closing speed
Coupling speed when closing
Diagnostics
EN
Pressing the motor control
button
Yes
Programmable: 0 s to 600 s
Yes: programmable reclosing
time delay from 0 to 255 min
Programmable: without or
without warning (fixed duration
of 2 s)
Programmable: stop - partial
re-opening - total re-opening
Programmable: without effect of
movement refused
Yes
Yes
Programmable: 10 possible
values
Programmable: 10 possible
values
Programmable: 5 possible
values
Saving and consulting data: cycle
counter, cycle counter with ob-
stacle detection, number of radio
channels memorised, history of
last 10 faults recorded
14

Publicité

Table des Matières
loading

Table des Matières