1.3
Technical data
Cutaway diagram of the head rail, closed at the bottom
20 mm
The mushroom (9 015 911) works in up and down
direction.
2
Installation
2.1
Assembly
2.1.1
57 x 51 mm and 58 x 56 mm head rail, open below
•
Fit the 2 adaptors (1) using 2 M 3 x 8 �olts (2) on the
motor shaft.
Tightening torque = 1.2 Nm
•
Connect the connection ca�le (3) to the motor.
•
Mushroom should �e positionned plug side
•
Insert the motor into the head rail (4).
•
Using the clips (5), attach the motor in the rail (4)
a�ove the pads (6).
•
The shaft can �e fitted into the adapter using a
headless screw (7).
If the tension of the clips (5) is insufficient, it is possible to stick up to 3 pads (6) one on top
of the other.
© 2009 Somfy SAS. All rights reserved. 12/2009
End limit switch capacity:
Direction of rotation:
Mushroom on
plug side
56 mm
Length
2 1
7
7
4
200 rotations
DOWN
Mushroom opposite
plug side
56 mm
6 Nm
10 Nm
18 Nm
306 mm
321 mm
341 mm
5
5
6
6
UP
2
1
7
3
7
4
21