Keep the working area clean. Do not use compressed air, jets of water or thinner to re-
move dirt or residuals from the machine. While cleaning, try as far as possible to prevent
dust from forming or rising.
CORGHI declines all liability for claims derived from the use of non-original spare parts
or accessories.
Scheduled maintenance:
The machine will periodically prompt maintenance to carry out. Failure to observe instruc-
tions could affect proper functioning of the machine.
- Make sure the condensation is draining from the filter-
regulator unit:
The regulating filter unit is equipped with a semiautomatic
device to drain the condensate. This device is automatically
activated whenever pneumatic supply to the machine is
cut off. Drain the condensate manually (1, Fig. 44) when the
level rises above level 2, Fig. 44.
To carry out every month.
- Clean and lubricate the tool head carriage guide (1,
Fig.45):
Clean with environmentally-friendly solvents and lubricate
with LIPLEX EP 2 lubricant or equivalent.
To carry out every two months.
- Lubricate the tool head unit translation screw (2,
Fig.45):
Clean with environmentally-friendly solvents and lubricate
with MOLYguard lube PTFE ISO 68 oil or equivalent.
To carry out every three months.
150
CAUTION
WARNING
WARNING
Artiglio Master J Operator manual
2
1
2
1
44
45