The belt is out of position
➥ Check the belt and adjust.
Mechanical parts are not turning freely and are preventing the motor from running
➥ Check that all rotating parts are turning freely.
Circuit board faulty
➥ Replace.
The switch (3-4 fi g.7) is broken.
➥ Replace.
A circuit board fuse has blown
➥ Replace and check the cause.
Faulty contact in a circuit board high voltage power cable plug or socket
➥ Disconnect the high voltage plug and connect the cables one at a time, in order to
discover the faulty contact.
The overload cutout trips
➥ Check for short circuits on the machine or motor electric systems.
Check the available kW and the requested kW by reducing the speed of the machine.
Switch faulty.
Faulty diode on feeder circuit board.
WARNING
The "Spare parts" manual does not authorize the user to work on the machine, with
the exclusion of the procedures explicitly described in the operating instructions. It
does allow the user to provide precise information to the technical service centre,
cutting back on down time and repair time.
WARNING
Corghi declines all liability for claims deriving from the use of non-original spares or
accessories.
WARNING
Any procedure aimed at changing the pressure setting on the pressure relief device
is strictly prohibited.
The manufacturer declines any and all responsibility for damage caused by tamper-
ing with these regulators.
WARNING
Before proceeding with any adjustment or maintenance work, disconnect the
40

The motor fuse frequently blows.

The machine does not run

MAINTENANCE

WIND-TWIST operator's manual