Auto Pump Speed Mode – with Purge/Vent Device
Accessory Only
The default setting for vent operating mode is "Au-to Pump Speed"
(Win 125 = 2). When activated the procedure guarantees that the
pump is slowed down properly modulating in automated way the
vent valve.
The vent could damage the pump. Please, use the Agilent "Auto Pump Speed"
CAUTION!
mode or refer to Agilent personnel.
On Command Mode – with Purge/Vent Device
Accessory Only
If WIN 125 = 1 the vent valve is opened via serial but the "Auto Pump
Speed" mode is automatically activated until the speed of the pump is
100 Hz.
Auto Time Mode – with Purge/Vent Device
Accessory Only
If WIN 125 = 0 the vent valve is opened as a func-tion of time (see the
figure below for details). The timing are configurable through WIN
126 (Vent Valve Opening Delay) and WIN 147 (Vent Valve Opening
Time).
Turbo-V 750/850 TwisTorr User Manual / 87-901-020-01