3.
OPERATING FUNCTIONS
3.4
Software language setup
With the electrical power supply stopped upstream
of the appliance for longer than 100 hours, reset the
software language.
The oven is set to Italian.
To select the language you require, press and hold the "GO!" icon
and the "ENTER" key at the same time (Fig. 2/A+C).
Press the "TEST" icon (Part. D) and select the "FACTORY SET-
TINGS" icon (Fig. 2/E).
Press the "CONFIRM" icon (Fig. 2/F) and use the "MINUS" and
"PLUS" icons (Fig. 2/G) to select the language you require.
Press the "CONFIRM" (Fig. 2/F) button to confirm your choice and
press the "ESC" key several times (Fig. 2/B) to return to the Home
Page.
3.5
Description of stop modes
The description of the various stop modes are described as fol-
lows:
In the event of imminent danger, close all of the lock-
ing devices connected to the appliance (Electrical -
Water - Gas).
1. Emergency stop
In situations or circumstances that could be dangerous, shut off the
electricity upstream of the oven.
Restarting:
To restart the production cycle, contact the authorised service cen-
tre.
2. Stoppage during a work phase
To stop the operation of the production cycle, proceed as follows:
Press "ENTER" (Fig 2/C) to stop the operations in progress and
press the "ESC" key (Fig 2/B) several times to return to the Home
Page.
Restarting:
To restart the production cycle after a shutdown, follow the procedure given in: Daily activation
3. Stop due to opening the door during operation
The appliance can be immediately stopped by opening the door.
Restarting:
After having resolved the issue that made it necessary to open the door, an authorised operator can restart the
appliance by closing the door.
The appliance has hot surfaces: glass, door and front side. When the oven is hot, open the door
carefully, standing to the side of the appliance to avoid direct heat: the steam accumulated may
cause burns.
THE PRESENT MANUAL IS PROPERT Y OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
A
Fig.2
- 9 -
9
ALARM LIST
CORE PROBE
FACTORY
SETTINGS
E
TEST
SETTINGS
RESULTS TEST
B
C
FACTORY
SETTINGS
Languages
Italian
F
G
D

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cmfg sérieCmfg6Cmfe102Cmfe10

Table des Matières