3 Installation
3.1 Routing details
Routing for a standard triple-point lock are required to install the blueMotion
motorised multipoint locking system. In addition, routings for the motor housing
are required as indicated in the following diagrams.
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
Notice: If a non-Winkhaus access control system is used, the signal
will have to be transmitted as a potential free contact (prepare
a potential free contact).
Notice: The magnetic bush has to be ordered separately.
In keep rail / extension keep set a bore diameter of 13.5 mm is to
be drilled (see figure 3.1-1).
Notice: They are profile cylinder in accordance with EN 1303
(Corrosion Resistance Class C) generally with cam position
± 30°, in each case with smooth-running "free to turn" function,
the use of a FZG cylinder is recommended.
Caution! Exceptions are panicLock blueMotion EN 179 / 1125.
Only panic free to turn cylinders with FZG anti-barricade
function and cam position max. ± 30 ° can be used!
DANGER! With panicLock blueMotion (BM) a rechargeable
battery with charging connection (part no. 2121455) is to be
installed!
Caution! A use of blueMotion with frame power supply
"T-NETZTEIL RAHMEN 24 V DC" is only possible without
battery, therefore no use as a panic lock in escape doors!