Installation, Operating and
Maintenance Instructions
a) All types of cylinder locks do not affect the proper escape door function.
b) All locking cylinders with proof of suitability according to the FZG Test
Guideline Gütegemeinschaft locks and fittings e. V. as well as "profile
cylinder in accordance with EN 1303 (corrosion resistance class C) with
cam position ± 30°" may be used without further proof.
c) An emergency power back up must ensure that the bolt always reaches
the end position in the event of a power failure.
9.3 Panic locking system to EN 1125
Article
VS-
Func-
no.
type
tion
T-BM-EN
B
1125
a) b) c)
Maximum door sash height: 2500 mm
Maximum door sash width: 1500 mm
All locks alternatively with 1.5 mm reduced latch. If the cylinder (PZ, RZ) standard
or half-cylinder is the escape door function of the lock is only guaranteed when
the key is removed.
a) All locking cylinders with proof of suitability according to the FZG Test
Guideline Gütegemeinschaft locks and fittings e. V. as well as "profile
cylinder in accordance with EN 1303 (corrosion resistance class C) with
cam position ± 30°" may be used without further proof.
b) The closure may be equipped with maximum of two additional bolt locks.
c) An emergency power back up must ensure that the bolt always reaches
the end position in the event of a power failure.
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes