Caution! For the combination of the blueMotion BM + access
control system, the Winkhaus power supply T-HT NETZTEIL
24 V DC / 2,5 A must not be overloaded with more than 2.5 A!
With the combination with frame power supply T-NETZTEIL
RAHM. 24 V DC the power supply should be charged max.
permanently with 1 A and max. 2 A will be charged for 2 s!
Caution! The use of T-NETZTEIL RAHMEN 24 V DC with
blueMotion is only possible with T-SET KÜ-T1 FT INTEG-BM
(5040512 / housing EV-G) and only without battery!

Battery

Notice: Secures defined state of system in the event of a power
outage (it is not on alternative means of power supply for
continuous operation).
It is mandatory to replace the battery approx. every 3 years or
1.000 charging cycles to ensure trouble free operation.
Caution! The antipanic version panicLock blueMotion
EN 179 / 1125, must always be mounted with a battery for
system zeroing.
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49  369  3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
Rechargeable battery for mounting on DIN rail
to avoid system failure in the event of a power
outage
T-HT AKKU MIT LADESCHALTUNG
27
5044745
2121455
EN