Installation, Operating and
Maintenance Instructions
EN
The opening impulse is transmitted by the swing door opener directly to
the blueMotion via potential-free contact.
Decontrol signal from blue motion to the DORMA swing door opener via a
potential free contact as soon as or as long as the swing door opener
must swing the sash.
3
Do not connect a transponder antenna here.
For blueMotion + swing door drive and transponders the following parts are be
used:
• T-STEUERUNG FÜR FREMD-ZKS (2194689)
• T-HT TRANSPONDERSET T02 EAV BL (2410265)
• T-HT NETZTEIL 12 V DC / 2 A for Transponder (2469777)
• T-HT NETZTEIL 24 V DC / 2,5 A for blueMotion (2126934)
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
Notice:
With application of a swing door opener, attention to
installation points:
• Please read manufacturers instructions for connection the
swing door opener.
• Cable length and wire cross section of signal input and
output cable dependse on instructions of swing door opener
manufacturers.
• The opening impulse of the entry control system goes
directly to the swing door opener and then to the external
control, per potential-free contact.
• The decontrol signal of the blueMotion to swing door opener
takes place over a potential-free contact (clamps 6 to 8 of
the external control unit).
• The signal is made as soon as a manual or electronic control
of the lock takes place. The signal continues until the swing
door opener return to the close position.
60
5044745