Installation, Operating and
Maintenance Instructions
Notice: The positioning of
frame power supply and
cable transition on the hinge
side is recommended, either
between lower / middle door
hinge or in each case approx.
10 cm above / below the
middle door hinge.
Figure 3.8.2-10: Wiring blueMotion with
and frame power supply
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
Description
230 V AC
fingerprint IDENCOM BioKey INSIDE
(sash side)
71
white + 24 V DC
brown 0 V
green
yellow
grey
pink (not assigned)
green / yellow = input for external
potential-free contact
(e.g. unlocking via
intercom / "open"
button)
Notice!
max. 40 m extendable
(min. 5 x 0,8 mm
Set of cable transition
T-SET KÜ-T1 FT IN-
TEG-BM 3,5 + 1,5 M EST
including housing EV-G +
cover plate (depends on
the faceplate / material
type), plug-in
Cable transition frame
part T-KÜ-T1 RT KABEL
0,6M RNT, for frame
power supply
T-BM ... including motor
housing
Frame power supply
T-NETZTEILRAHM. 24 V
DC 1 A (2 A/2 S)
Access control system
Fingerprint IDENCOM
BioKey INSIDE Basic
without App
Fingerprint IDENCOM
BioKey INSIDE with App
5044745
EN
3
}
external opening
signal
)
2
Art.-No.
5040512
5040504
on
request
5038589
IDENCOM
680 804
692 814