Installation, Operating and
Maintenance Instructions
EN
3
Figure 3.6.1-1: Installing the wireless receiver
No. Terminals wireless receiver
1
"Break contact (NC)", is not necessary
2
"Contact (C)", from the wireless receiver to the "Open" button of the
external control unit (terminal 11)
3
"Make contact (NO)", from the wireless receiver to the "Open" button
of the external control unit (terminal 12)
4
"12 V DC resp. 24 V DC", power supply, e.g. from Winkhaus power
supply unit (connect with white wire of the cable transition)
5
"0 V DC", power supply, e.g. from Winkhaus power supply unit
(connect with brown wire of the cable transition)
6
"Auxiliary antenna / ANT" (not required)
7
"Auxiliary antenna / GND" (not required)
Figure 3.6.1-2: Adjustment of the jumper for voltage selection
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
12 V
54
No. Name
P1 button
green LED
red LED
Buzzer
Relay
Jumper 12 V / 24 V
Caution! blueMotion
must be operated with
24 V DC.
24 V = Delivery Status
5044745