Installation, Operating and
Maintenance Instructions
Notice: If you are planning to use non Winkhaus power supply
units please take note of the following information:
• 24 V DC power supply (stabilized)
• min. 1,5 A continuous current (min. 2 A peak current)
• min. 36 W
LED-Signal
Battery (green)
on
off
off
Notice: It is imperative replacing the battery approx. every
3 years or 1.000 charging cycles / power outage to ensure
reliable, troublefree operation.
Caution! The following must be observed for use of
interruption-free power supply (UPS):
• The UPS must deliver following exit: 24 V DC, stabilizes, 1,5 A
• When using a UPS, it is strongly recommended to use the
battery pack.
• The above-mentioned output is clamped to the input of the
battery pack like the standard power supply.
• With the tension supply of the UPS, the manufacturer
statements (wire cross section, cutout, et cetera) are to
observed!
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
LED-Signal
Battery (yellow)
on
on
off
51
Status
mains-operation
battery-operation
no power supply / power outage
5044745
EN
3