Error
Motor is
running-
voltmeter
shows no
voltage-sockets
are without
power
Engine running,
but very
restless and
uneven
Cable pull
starter
is blocked and
cannot be
pull
throughMotor
starts
not
Cable pull
starter
can be
combined with
Resistance
pull through
Motor starts
not
EN
V. 1.1
Possible cause
Starting current of the
Consumers to
high.
False
Fuel or oil
Cable starter possibly
defective
Incorrect
commissioning
Solution
Contact customer service and
describe the problem. Tell the
Customer Service which consumers were
connected to the appliance during the
last use.
Check that the air filter is firmly seated
and undamaged. The air filter must not
draw false air. Clean any dirt from the
air filter core. Only refuel the appliance
with unleaded petrol (normal petrol,
Super, Super Plus). Do not mix under any
circumstances
do not add other additives or oils to the
gasoline and do not use E10 fuel.
Remove the pull-wire starter. If it can
be pulled through with resistance
when dismantled, the starter is in good
condition. If the cable pull can be pulled
through without resistance, it is defective.
Contact our customer service and
describe the problem.
Please carefully follow all the steps for
preparing and switching on the motor in
section Commissioning, p. 20.
33