8.2.2.8.1 Measurement Data Information
Lower Value: This value indicates the start of the measuring range (lowest possible mea­
sured value). The lowest possible measured value of compression force transducers is
the end of the measuring range as a negative number.
Upper Value: This value indicates the end of the measuring range (highest possible mea­
sured value).
Unit code: The IO-Link standard defines various units. Here you will find the code of the
unit being used (usually Newton) as per the IO-Link standard.
U10M
ELECTRICAL CONNECTION
Authoriza­
Data type
tion
ReadOnly
UInteger32T 4
ReadOnly
UInteger32T 4
ReadOnly
Float32T
ReadOnly
Float32T
ReadOnly
Float32T
Data
Name
size
(bytes)
Overload
Counter
Compressive
Force
Overload
Counter
Tensile Force
4
Oscillation
Bandwidth
Percentage
4
Compressive
Force Max
4
Tensile Force
Max
Description
Number of
overload
processes in
compression
Number of
overload
processes in
tension
Degree of
consumption
of the
dynamic over­
load reserve
Highest
compressive
force ever
measured
Highest
tensile
force ever
measured
57