Where the switch is to be triggered on a falling force:
u
Switch the logic to "Low active".
u
Set the "SP1" field to the higher force (in the logic defined above).
u
To make the new switchover on a falling force at a lower force value, enter the lower
force value in SP2. If you set both values the same, the switch will work without hys­
teresis.
Window mode
The range can be monitored in Window mode.
S
Enter the two forces that define the switching points, SP1 and SP2. Their order is irrel­
evant.
S
If you want, you can enter an identical hysteresis for the upper and lower switching
points.
S
You can invert the output by selecting "High active" or "Low active". When "High active"
is selected, the output is logical 1 if the value is in the window range.
The state of the limit value switch can be outputted via two digital outputs in the form of
a 24 V switching signal in the electronics.
Index
Sub-
(hex)
index
(hex)
0x003C 0x00
0x003C 0x01
0x003C 0x02
0x003D 0x00
46
Authorization
ReadWrite
ReadWrite
ReadWrite
ReadWrite
Data type
Data
size
(bytes)
RecordT
8
Float32T
4
Float32T
4
RecordT
6
Name
Description
SSC1
Access all
Param
parameters
(SP1, SP2)
for Switching
Channel 1
SSC1 SP1
Switching
point for
Switching
Channel 1
SSC1 SP2
Second
switching
point for
Switching
Channel 2
SSC1
Access all
Config
configurations
for Switching
Channel 1