To transfer the lateral forces specified in the data sheet, we recommend using the center­
ing aids.
The customer's own structural elements (contact surfaces) must meet the following con­
ditions:
S
They must be in parallel to each other.
S
They must be paint-free.
S
They must be oil and grease-free, cleaning can be implemented e.g. with RMS-1
(HBM ordering number 1-RMS1).
S
They must be sufficiently hard (min. HRC 40).
S
They must be sufficiently rigid so that they do not flex.
S
The flatness of the contact surface is ideal when a tolerance of 0.005 mm is not
exceeded under load.
S
The screws used must comply with the property class specified in the following table
and tightened with the specified tightening torque. The threaded holes must be suffi­
ciently stable to allow bolts of the specified property classes to be used.
Nominal
(rated) force
1.25 - 5 kN
12.5 - 25 kN
50 - 125 kN
250 kN
500 kN
1.25 MN
Tab. 7.8
Specification of screws and tightening torques for mounting without adapter
1)
Lightly oiled bolts
26
Tightening
1)
torque M
B
Num­
in NVm
ber
9
8
15
8
76
12
150
16
380
16
890
24
Bolts for transducer mounting
Metric
M6 x 40
M6 x 40
M10 x 1.25 x 55
M12 x 1.25 x 80
M16 x 1.5 x 100
M22 x 1.5 x 150
Property
UNF
class
8.8
1/4"
10.9
1/4"
10.9
3/8"
12.9
1/2"
12.9
5/8"
12.9
7/8"
MECHANICAL INSTALLATION
Grade
5
8
8
9
9
9