Error / info
code
The power pack has too high
0013
0014
To start on the set rpm
No valid wall saw tool, start pre-
0015
The potentiometer can not
0016
Connected to prime tool
0017
Connected to prime tool
0018
The power pack has too high
0019
0020
The tool has too high tempera-
0021
The feeding motor is overloa-
0022
Tool service within 50h.
48
Message
temperature
vented
start.
WS220
WS8
temperature
ture
ded
Cause
The water is not connected.
The incoming cooling water is
too warm.
The flow is low.
No compatible tool is connec-
ted
The potentiometer is not set to
neutral position.
The water is not connected.
The incoming cooling water is
too warm.
The flow is low.
The water is not connected.
The incoming cooling water is
too warm.
The flow is low.
The saw has hit the track end
stop.
Clean the track from slurry.
The blade is stuck.
Action
Do a check of the water con-
nection.
Do a check of the water flow
and the temperature.
Speak to an approved Husqvar-
na service center.
Try to connect a different tool.
Speak to an approved Husqvar-
na service center.
Set the potentiometer in neutral
position.
Speak to an approved Husqvar-
na service center.
Do a check of the water con-
nection.
Do a check of the water flow
and the temperature.
Speak to an approved Husqvar-
na service center.
Do a check of the water con-
nection.
Do a check of the water flow
and the temperature.
Speak to an approved Husqvar-
na service center.
Clean the track.
Make sure that the wall saw
is aasembled correctly on the
track.
Speak to an approved Husqvar-
na service center.
Time for service within 50
hours.
2092 - 003 - 08.08.2024