To stop the power pack and the power tool
1. Push the stop button (B) on the power pack.
B
2. Close the water supply to the power pack.
Status indication lamps
When the product is connected, the lamps 1-5 comes on
for some seconds.
1
2
3
4
1. Phase lamp (green)
2. Phase lamp (green)
3. Phase lamp (green)
4. Service indicator (yellow)
5. Warning indicator (red)
For more information about the status indication lamps,
refer to
Explanation of the power pack status indication
lamps on page 45 .
34
5
Warning indicator
CAUTION:
the product when the warning indicator is
on. Risk of damage to the product.
If the warning indicator (red lamp) comes on, stop the
To stop the product on page 33 .
product. Refer to
Radio communication system
CAUTION:
regarding the operation require connection
with the CAN bus cable. Refer to
operate the product with the remote control
connected with a CAN bus cable on page
36 .
Before you can operate the connected power tool, you
must do a pairing operation between the remote control
and the product. It is also necessary to do the pairing
operation when the product is connected to the remote
control with CAN bus cable.
The remote control can only control the connected
product.
If the supplied remote control is replaced, you must do
a pairing operation between the remote control and the
product again.
If it is necessary to interchange the remote controls
between 2 power pack units, you must do a pairing
operation between the interchanged remote control and
the product.
To do a pairing operation between the remote control
and the power pack
CAUTION:
regarding the operation require connection
with the CAN bus cable. Refer to
operate the product with the remote control
connected with a CAN bus cable on page
36 .
Note:
The pairing operation can also be done when
CAN bus cable is connected to the power pack.
1. Make sure that a charged battery is installed in the
remote control.
2. Start the power pack. Refer to
pack on page 32 .
3. Start the remote control. Refer to
remote control on page 36 .
Do not continue to operate
Clarify if the circumstances
To
Clarify if the circumstances
To
To start the power
To operate the
2092 - 003 - 08.08.2024