"Third party licences"
Shows the open source licences for the operating
system and the app licences in the remote control.
Control diagnostics
In "Control diagnostics" you can do function tests of the
controls on the remote control. Each control is shown in
the display. The control indicators in the display changes
from white to orange when you do the function tests.
Operate a control on the remote control to its maximum.
The control operates correctly when the control indicator
shows 0% in the middle and -100% resp. 100% at the
end positions.
CONTROL DIAGNOSTICS
O% O%
PRESS AND HOLD BACK TO EXIT
Information center display
C
A
B
Information center
The information center display on the remote control
shows the information that follows about the remote
control:
•
If the remote control is on or off.
•
Error codes. Refer to
error codes on page 49 .
•
Pairing operation between the remote control and
the product. Refer to
between the remote control and the power pack on
page 34 .
40
1
2
D
Remote control HMI display
To do a pairing operation
•
The radio signal strength (A) between the remote
control and the product. The same symbols are
also shown in the top bar on the display. Refer to
Symbols in the top bar on the display on page 8
Radio signal
There are 4 levels of radio signal
strength.
Radio signal is in standby mode.
The remote control does not oper-
ate correctly.
No radio signal.
•
Battery status (B). The same symbols are also
shown in the top bar on the display. Refer to
control battery on page 40 .
State of charge
There are 5 levels of charge for the
battery.
Battery fault.
Cable connection between the re-
mote control and the product.
There are 2 buttons for the information center display.
The left side button (C) moves to the next symbol in the
display. The right button (D) makes the selection.
Remote control battery
WARNING:
control battery and the charger, you
must read and understand
instructions on page 10 and Battery safety
on page 12 .
Note:
It is necessary to charge the battery before you
use the remote control for the first time.
Note:
If the battery does not operate for 5 days it goes
into shipping mode. When the batteries are in shipping
mode, you must connect them to the charger to exit the
shipping mode.
Note:
Put the battery in the charger for approximately
15 seconds to start the battery if it is in sleep mode.
The battery has a state of charge symbol on the display
and the information center display, refer to
the top bar on the display on page 8 and Information
center display on page 40 . It is not possible to operate
Symbol
Remote
Symbol
Before you use the remote
General safety
Symbols in
2092 - 003 - 08.08.2024