Section 5
Operation
•
Press the button (4 times) and display (7)
will show the message "P04".
•
Press the button (5 times) and display (7)
will show the message "P05".
•
Press the button (6 times) and display (7)
will show the message "P06".
•
Press the button (7 times) and display (7)
will show the message "P07".
•
Press the button (8 times) and display (7)
will show the message "P08".
•
Press the button (9 times) and display (7)
will show the message "P09".
•
Press the button (10 times) and display (7)
will show the message "P10".
•
Press the button (11 times) and display (7)
will show the message "P11".
•
Press the button (12 times) and display (7)
will show the message "P12".
•
Press the button (13 times) and display (7)
will show the message "P13".
Table of pre-set regeneration programs
P01
Delicate steam
P02
Standard steam
P03
Boiled steam
P04
Moist stews braised
P05
Confectionery
Fried breaded gilding Stage 1 - Convection / 230°C / Humidity 100% / 1' / fan speed max
P06
P07
Grilled foods
30 Combination Oven Installation and Operation Manual
From P16 to P94 the programs are described in
the following table. It is possible to personalise it
(use the knob to select quickly these programs).
Stage 1 - Steam / 90°C / 1' / fan speed max
Stage 2 - Steam / 90°C / 2' / fan speed max
Stage 3 - Steam / 85°C / 20' / fan speed max
Stage 4 - Steam / 84°C / 8' / fan speed max
Stage 1 - Steam / 100°C / 1' / fan speed max
Stage 2 - Steam / 100°C / 1' / fan speed max
Stage 3 - Steam / 98°C / 5' / fan speed max
Stage 4 - Steam / 96°C / 12' / fan speed max
Stage 1 - Steam / 110°C / 1' / fan speed max
Stage 2 - Steam / 98°C / 1' / fan speed max
Stage 3 - Steam / 86°C / Core temperature 68°C / fan speed max
Stage 4 - Steam / 84°C / Core temperature 72°C / fan speed max
Stage 1 - Combined / 140°C / Humidity 90% / 1' / fan speed max
Stage 2 - Combined / 125°C / Humidity 70% / Final core temperature 60°C / fan speed max
Stage 3 - Combined / 135°C / Humidity 30% / Final core temperature 72°C/ fan speed max
Stage 4 - Combined / 155°C / Humidity 30% / Core temperature 80°C / fan speed max
Stage 1 - Convection / 170°C / Humidity 100% / 1' / fan speed max
Stage 2 - Convection / 170°C / Humidity 40% / 10' / fan speed max
Stage 3 - Convection / 165°C / Humidity 30% / 6' / fan speed max
Stage 4 - Convection / 160°C / Humidity 0% / 4' / fan speed max
Stage 2 - Convection / 205°C / Humidity 30% / 5' / fan speed max
Stage 3 - Convection / 210°C / Humidity 10% / 2' / fan speed max
Stage 4 - Convection / 220°C / Humidity 0% / 1' / fan speed max
Stage 1 - Convection / 255°C / Humidity 100% / 1' / fan speed max
Stage 2 - Convection / 240°C / Humidity 0% / 5' / fan speed max
Stage 3 - Convection / 245°C / Humidity 0% / 2' / fan speed max
Stage 4 - Convection / 250°C / Humidity 0% / 1' / fan speed max
•
Press the button (14 times) and display (7)
will show the message "P14".
•
Press the button (15 times) and display (7)
will show the message "P15".
•
Use the knob until display (7) shows the
message "S01".
•
Use the knob until display (7) shows the
message "S02".
•
Use the knob until display (7) shows the
message "S03".
•
Use the knob until display (7) shows the
message "S04".
•
Use the knob until display (7) shows the
message "S05".
•
Use the knob until display (7) shows the
message "OUT", exit the program.
•
Press button (16) to start the selected
program.