CONNECTING THE GAS EXHAUST VENT
IMPORTANT _________________________
Make the connection in compliance with
all relevant local and legal requirements,
using
appropriate
materials.
IMPORTANT _________________________
Maximum exhaust gas temperature at the
outlet is approximately 750°F.
CONNECTING TO A
FAN EXTRACTOR HOOD
Position the appliance underneath hood (C) as
shown in the diagram.
IMPORTANT _________________________
The
gas
supply
automatically
when
extraction system is switched on.
C
Minimum
12"
and
recommended
valve
must
open
the
fan
of
the
GAS SUPPLY CONVERSION
WARNING
Before proceeding with the
conversion, shut off gas supply before
disconnecting the electrical power.
WARNING Before performing any service
that
involves
electrical
disconnection and/or exposure to electrical
components, always follow the Electrical
LOCKOUT/TAGOUT Procedure. Disconnect
all circuits. Failure to comply can cause
property damage, injury or death.
The manufacturer has tested the appliance with its
own mains gas, identifi ed by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1. Turn off gas supply valve (A).
2. Change the burner nozzle (see page 43).
3. Remove the testing gas sticker from the data
plate (B) and apply the new one to identify the
gas being used.
4. Start the "Conversion of gas supply " procedure.
5. Carry out the appliance testing procedure (see
page 44).
IMPORTANT _________________________
Upon completing the operation, make sure
there are no gas leaks or malfunctions.
WARNING
Do not use an open fl ame to
test for gas leaks. Use a commercial leak
detector or a soap and water solution.
WARNING
The gas supply conversion
must be made by an authorized service agent
in accordance with the manufacturer's
specifi cations and all applicable codes
and requirements of the authority having
jurisdiction. If the procedures in these
instructions are not followed exactly, a
fi re, an explosion or production of carbon
monoxide may result causing property
damage, personal injury or death. An
authorized service agent is responsible
for proper conversion. Installation is not
proper and complete until the operation
of the converted appliance is checked as
specifi ed in the manufacturer's instructions
supplied with the kit.
Combination Oven Installation and Operation Manual
Section 4
Handling and Installation
connection
or
23