WATER CONNECTION
WARNING
Make
compliance
with
requirements,
using
recommended materials.
IMPORTANT _________________________
This appliance is to be installed to comply
with the applicable federal, state, or local
plumbing codes having jurisdiction.
B
Connect the mains line to the appliance's connection
pipe, fi tting a shut-off tap (B) to allow the water
supply to be cut off when necessary.
IMPORTANT _________________________
Wherever chemicals are used in the water
supply
system
for
example
chloramines
hypochlorite, it is necessary to install a
fi lter to guarantee their removal.
IMPORTANT _________________________
Check water pipes and fi ttings for corroded
parts, they may pollute the water inside
the appliance.
IMPORTANT _________________________
If the water features are such to require a
treatment system and the shower launching
accessory is installed in the oven (LDR610
for models FX61-101-82- 122 and LDL only
for models FX201-202), the water supplied
by the latter must also be treated.
the
connection
the
relevant
appropriate
for
water
sanifi cation,
or
sodium
WATER: RACCOMANDATIONS FOR USE
IMPORTANT _________________________
in
legal
To maintain the hygienic features and
and
integrity of the stainless steel over time
(required for protection against corrosion),
daily wash the cooking chamber (see
page 35) with suitable detergents and
completely dry it before use.
IMPORTANT _________________________
Perform
treatment system (where it is installed) to
ensure its proper functionality.
IMPORTANT _________________________
Be sure to use new and fully functional
accessories.
IMPORTANT _________________________
Use
only
cleaning
appliance.
IMPORTANT _________________________
If the water features are such to require
a treatment system, do not introduce
untreated
during cooking. For example: if the type of
cooking requires the presence of a pan full
of water on the bottom pan tray, the water
must have the features shown in the table
on page 19.
Combination Oven Installation and Operation Manual
Handling and Installation
maintenance
of
detergents,
chemicals
procedures
suitable
water
inside
Section 4
the
water
and
for
the
the
chamber
21