ADJUSTING THE WATER PRESSURE
To carry out this operation, proceed as follows:
1. Undo screws to remove side panel (A).
2. Turn on water supply valve (B).
3. Unscrew ring nut (C).
4. Turn the cooking chamber water intake screw
(D) to bring the pressure reading on pressure
gauge (E) to 14.5 psi.
If the water pressure is too low, install a device
to increase the pressure.
5. Retighten ring nut (C).
6. Replace side panel (A), replace and tighten all
screws.
7. Turn water supply valve (B), to the OFF position
when the operation is complete.
E
C
26 Combination Oven Installation and Operation Manual
A
D
B