System Display Mode Selection
Setting the monitor output attenuate level (mode No.6)
Various types of audio equipment work at different reference levels. The monitor output attenuate level reduces
the level of the analog outputs. This feature, when used in combination with the +4/-10 dB pad switch, makes
it possible to vary the analog output level over a 28 dB range. This virtually eliminates any likelihood of level
incompatibility with other equipment.
(1) Attenuate level setting methods
This level can be set in the following 3 ways.
1) The level is set using the SETTING buttons or SETTING dial.
2) The level which has been preset in one of the LOCATE button is used.
3) The level is defined by the user by the LOCATE LAST button and recalled for use.
Example:
(2) Setting the attenuate level
Button operated
Operation
Display
SETTING button (for-
Each time the forward button is pressed, the setting is
The digital attenuate
ward or reverse)
incremented by 1; conversely, each time the reverse button _ setting appears on the
is pressed, the setting is decremented by 1.
counter display.
SETTING dial
The setting is continuously incremented or decremented by
turning the dial in the UP or DOWN direction.
The attenuate level (DATT) can be set from 200 (approx. -14 dB) to 1024 (0 dB). The attenuate level is
20 x log,, "pate [dB]. The setting established after initialization is 1024.
(3) Using a preset level in a LOCATE button
There are four factory preset levels programmed into LOCATE 1-4 buttons which can be easily recalled by
simply pressing the buttons.
Press the LOCATE button 2 to set the level to-2 dB. While this button is kept depressed, the decibel level
("-2" in this case) is displayed and when the button is released, it is set to a value (813) for establishing the
—2 dB level.
LOCATE button No.
Default setting
Display
LOCATE 1
~0 dB (=1024)
"~00"—A1024
LOCATE 2
—2 dB (=813)
"02"
A0813
LOCATE 3
~4 dB (=646)
"~04" A0646
LOCATE 4
—6 dB (=513)
"06" -A0513
(4) Using a setting which has been entered by the user in the LOCATE LAST button by recalling it
Setting method:
Set the attenuate level to the desired value.
Keep the LOCATE LAST button depressed (for at least 1.5 or so sec.).
After "- - -" is displayed, "-PP" appears indicating the value is stored.