Zfi Camera Settings Menu; Zone Titling Menu - Videotec ULISSE Manuel D'instructions

Masquer les pouces Voir aussi pour ULISSE:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

9.6.3 ZFI camera settings menu

01. Zoom: This sets the maximum zoom level that
the motorised lens can achieve.
02. Common Wire: If enabled, it manages the
motorised common wire lenses; if disabled, it
manages those with inversed polarity.
04. Area Titling: Allows access to the area titling
submenu.
05. Zone Masking: This provides access to the zone
masking management submenu.
06. Housing Serial Port: Allows access to the
submenu for managing the housing serial port.
07. Polarity: Allows access to the submenu for
managing the polarity of the Zoom, Focus and
Iris motors.
ZFI CAMERA SETTINGS
------------------------
1>ZOOM
2 COMMON WIRE
4 ZONE TITLING
5 ZONE MASKING
6 HOUSING SERIAL PORT
7 POLARITY
Fig. 61

9.6.3.1 Zone titling menu

This function allows setting up to 8 areas (variable
dimension) with titling option.
From the Zone Titling menu it is possible to set the
following parameters:
01. Number: Selects the area to be edited.
02. Enabling: Enables the message linked to the
related zone to be displayed on the screen.
03. Start: Sets the initial position of the area.
04. Stop: sets the final position of the area.
05. Text: Modifies the text which is displayed when
moving within the zone.
:
30x
:
N
>
>
>
>
ZONE TITLING
------------------------
1>NR.
:
2 ENAB.:
3 START: +
4 STOP : +
5 TEXT : ZONE 1
Fig. 62
Example: To enable titling of zone 1 when the device
is between +15° and +45°, it is necessary to:
• Enable area titling by setting Y as the value of
Enabling.
• Set 1 as the value of parameter Nr.
• Set +015.00 as the value of parameter Start.
• Set +045.00 as the value of parameter Stop.
• If necessary, edit the displayed text by selecting
Text.
Setting the Start and Stop values of the
j
menu to zero will disable text display. If
there are overlapping areas, the area with
the lowest number will prevail.
To define zones proceed in a clockwise
j
direction, as shown in the figure.
Stop2=225°
270°
180°
Start2=170°
Fig. 63
1
N
0.00
0.00
Start1=15°
Stop1=45°
90°
29