7.2.4.2 Alarm contact and relay connections

+
V
O1 C1
Vdc
O2 C2
Fig. 33
TERMINALS
DESCRIPTION
F1-F2
Additional lines
O1-C1 and
Clean output contacts, can be activated by
O2-C2
alarm or by user control
AL1, AL2, AL3,
Live controlled alarm inputs referring to
common COM
AL4 and COM
Tab. 07
20
7.2.5 Connecting the Ethernet cable
(for IP board version only)
To connect the net cable a UTP, Category 5E or
superior, 4 pair with a max length of 100m. is needed.
RS232
j
Crimp the RJ45 connector on the ethernet cable.
Crimping should be straight-through if passing via
a hub or switch while it should be crossover if you
are connecting directly to the PC for the necessary
checks.
Connect the crimped net cable to connector RJ45
located on the base of the unit.
Signal
Fig. 34
The example below shows a typical installation.
Fig. 35
Telemetry transmission and video signal
pass through the Ethernet cable. Do not
connect cable RS485 and the video cable.
UTP cat 5E
Personal
Computer
Hub / Switch
UTP cat 5E