Electricals
ABSORBED POWER
oven top element:
3500 + 1000W 230V - 3500 + 1000W 240V
oven bottom element:
3000W 230V - 3000W 240V
round element (hot air): 2x1300W 240V or 1x2500W 240V
lamp:
3x25W
hot air fan motor:
2x44W or 1x44W
cooling fan motor:
44W
induction modules:
3600W x 2 (30") or 3600W x 3 (36")
MAXIMUM ABSORBED POWER:
SUPPLY VOLTAGE:
Connection to the electrical power mains
WARNING
This apparatus must be earthed.
The appliance is only for domestic use.
The feed voltage and the absorbed power are as indicated on
the data plate attached to the left-hand side upright, which can
be seen when the oven door is open.
Connecting must be carried out by qualified personnel and in
accordance with the regulations currently in force.
The manufacturer can not be held responsible for any
damages to persons or objects caused by failure to observe
these instructions.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
The appliance must be connected to the mains through a
multipole circuit breaker with a contact-to-contact gap of at least
3 mm, making sure that the earth wire is not disconnected. For
connecting use a flexible cable remembering to make it long
enough to allow the appliance to be removed from its housing
unit when maintenance work is required.
The terminal box is located at the rear of the appliance. If a
new cable is fitted, route it through the clamp and make the
connections as shown in the diagram. The earth wire must be
cut longer than the other wires so that it will be the last to break
off in the event of the cable being tugged.
Having made the connection, tighten the cable clamp and
close the cover of the box.
CABLE TYPES
H05RR-F
H05SS-F
H05VV-F
H05RN-F
H05V2V2-F
FG7OR
7 - Electrical supply
Figure Diagram
A
220-240V~ or 240V~
1
2
(30")
R
PE
75cm
L
220-240V 3~ or 240V 3~
B
1
2
(30")
PE
R
75cm
L1
380-415V 2N~ or 415V 2N~
B
1
2
(30")
PE
R
75cm
L1
C
380-415V 3N~ or 415V 3N~
(30")
1
2
75cm
PE
R
S
L1
L2
(36")
90cm
(depending on model)
(depending on model)
(see data plate)
(see data plate)
Cable
3
4
5
3x10 mm²
N
3
4
5
4x6 mm²
S
T
L3
L2
3
4
5
4x6 mm²
S
L2
N
3
4
5
5x2,5 mm²
T
L3
N