DESCRIPTION
Sump oil temperature sensor failed
low
Sump oil temperature sensor, failed
high
Factory calibration compatibility
number wrong
Factory calibration block checksum
Power off block checksum
Diagnostic queue block checksum
Real time block checksum
Customer modifiable constants
checksum
Power interruption (code set after
power restored)
Real time write interruption
Hardware/Software not compatible
Short to battery, A solenoid circuit
Short to battery, B solenoid circuit
Short to battery, C solenoid circuit
Short to battery, D solenoid circuit
Short to battery, E solenoid circuit
Short to battery, F solenoid circuit
Short to battery, G solenoid circuit
Short to battery, H solenoid circuit
Short to battery, J solenoid circuit
Short to battery, N solenoid circuit
Short to ground, A solenoid circuit
Short to ground, B solenoid circuit
Short to ground, C solenoid circuit
Short to ground, D solenoid circuit
Short to ground, E solenoid circuit
Short to ground, F solenoid circuit
Short to ground, G solenoid circuit
158
Témoin
CHECK
Description des messages
TRANS
Use default value of 200°F
No
(93°C)
Use default value of 200°F
No
(93°C)
DNS, SOL OFF (Hydraulic
Yes
default), DNA
DNS, SOL OFF
Yes
(Hydraulic default), DNA
Use previous location or
No
factory calibration and reset
adaptive, DNA
Use previous location or
No
clear diagnostic queue, DNA
DNS, SOL OFF
Yes
(Hydraulic default), DNA
DNS, SOL OFF
Yes
(Hydraulic default), DNA
None (Hydraulic default
No
during interruption)
DNS, SOL OFF
Yes
(Hydraulic default), DNA
DNS, SOL OFF
(2)
Yes
(Hydraulic default), DNA
Yes
DNS, SOL OFF, DNA
Yes
DNS, SOL OFF, DNA
Yes
DNS, SOL OFF, DNA
Yes
DNS, SOL OFF, DNA
Yes
DNS, SOL OFF, DNA
No
Lock up inhibited, DNA
Yes
DNS, lock in a range
Differential lock inhibited
No
(3070 only), retarder
inhibited
No
Low and 1st inhibited
Low and 1st inhibited, allow
No
retarder
DNS, SOL OFF
Yes
(Hydraulic default), DNA
DNS, SOL OFF
Yes
(Hydraulic default), DNA
DNS, SOL OFF
Yes
(Hydraulic default), DNA
DNS, SOL OFF
Yes
(Hydraulic default), DNA
DNS, SOL OFF
Yes
(Hydraulic default), DNA
No
Lockup inhibited, DNA
DNS, SOL OFF
Yes
(Hydraulic default), DNA