Télécharger Imprimer la page

PREVOST H Serie Manuel De L'opérateur page 165

Masquer les pouces Voir aussi pour H Serie:

Publicité

LISTE ET DESCRIPTION DES CODES DE DIAGNOSTICS WORLD ALLISON
Code
Code
principal
secondaire
13
12
13
13
13
23
14
12
14
23
22
14
22
15
22
16
23
12
23
14
23
16
24
12
24
23
25
0
25
11
25
22
25
33
25
44
25
55
25
66
25
77
26
00
26
11
32
0
32
33
32
55
32
77
DESCRIPTION
ECU input voltage, low
ECU input voltage, medium low
ECU input voltage, high
Oil level sensor, failed low
Oil level sensor, failed high
Engine speed sensor
reasonableness test
Turbine speed sensor
reasonableness test
Output speed sensor
reasonableness test
Primary Shift Selector or RSI Link
Fault
Secondary Shift Selector or RSI
Link Fault
Shift Selector display line fault
Sump fluid temperature, cold
Sump fluid temperature, hot
Output speed sensor detected at 0
speed (Low)
Output speed sensor detected at 0
speed (1st)
Output speed sensor detected at 0
speed (2nd)
Output speed sensor detected at 0
speed (3rd)
Output speed sensor detected at 0
speed (4th)
Output speed sensor detected at 0
speed (5th)
Output speed sensor detected at 0
speed (6th)
Output speed sensor detected at 0
speed (R)
Throttle source not detected
Engine coolant source not detected
C3 pressure switch open, Low
range
C3 pressure switch open, 3rd range
C3 pressure switch open, 5th range
C3 pressure switch open, Reverse
range
Témoin
CHECK
TRANS
Yes
No
Yes
No
No
No
Yes
(1)
Yes
Yes
Yes
No
Yes
No
(1)
Yes
(1)
Yes
(1)
Yes
(1)
Yes
(1)
Yes
(1)
Yes
(1)
Yes
(1)
Yes
No
No
Yes
Yes
Yes
Yes
157
ANNEXE C
Description des messages
DNS, DNA, SOL OFF,
(Hydraulic default)
DNA
DNS, SOL OFF
(Hydraulic default)
None
None
Use default engine speed,
DNA
DNS, lock in current range
DNA
DNS, LOCK IN CURRENT
RANGE, DNA
Hold in last valid direction.
May cause "cateye" display
Hold in last valid direction
None, may cause "cateye"
display
DNS, lock in neutral
No upshifts above a
calibration range
DNS, lock in current range
(Low), DNA
DNS, lock in current range
(1st), DNA
DNS, lock in current range
(2nd), DNA
DNS, lock in current range
(3rd), DNA
DNS, lock in current range
(4th), DNA
DNS, lock in current range
(5th), DNA
DNS, lock in current range
(6th), DNA
DNS, lock in current range
(R), DNA
Use throttle default values,
DNA
Use default value of 0°F
DNS, lock in current range
(Low), DNA
DNS, lock in current range
(3rd), DNA
DNS, lock in current range
(5th), DNA
DNS, lock in current range
(R), DNA

Publicité

loading

Ce manuel est également adapté pour:

H3-45H3-41