3
Technical data
General data and operating conditions
3
Technical data
General data and operating conditions
Conformity and approval
CE
EAC
UL
Protection of persons and equipment
Type of protection
Earth leakage current
Insulation of control
circuits
Insulation resistance
Protective measures
EMC
Noise emission
Interference immunity
1)
Motor cable lengths depend on the inverter type and the switching frequency
100
2006/95/EC
Low−Voltage Directive
2004/108/EG
EMC Directive
TP TC 020/2011
Electromagnetic
compatibility of technical
(TR CU 020/2011)
means
TP TC 004/2011
On safety of low voltage
equipment
(TR CU 004/2011)
cULus
Power Conversion Equipment (File No. E132659)
EN 60529
NEMA 250
IEC/EN 61800−5−1
IEC/EN 61800−5−1
EN 61800−5−1
IEC/EN 61800−3
0.25 ... 11 kW
15 ... 90 kW
IEC/EN 61800−3
l
IP20
IP41 on the heatsink side for thermally separated mounting
(push−through technique).
Protection against contact in accordance with type 1
> 3.5 mA
Safe mains isolation through double (reinforced) insulation
< 2000 m site altitude: Overvoltage category III
> 2000 m site altitude: Overvoltage category II
Against short circuit, earth fault (protected against short to
earth on power−up, limited protection against short to earth
during operation), overvoltage, motor stalling, motor
overtemperature (input for PTC thermistor or thermal contact,
2
I
t monitoring)
Cable−guided, category C1 or C2 when using shielded motor
1)
cables
, dependent on the device variant with integrated
interference suppression or additional RFI/mains filter
E82xVxxxKxC0xx
E82xVxxxKxC2xx
E82EVxxxK4B3xx
E82xVxxxK4B2xx
Category C3
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
Eurasian Conformity
TR CU: Technical Regulation of
Customs Union
Observe stipulations and safety
instructions!
no additional measures
with external filter techniques
no additional measures
with external filter techniques
EDK82EV113 DE/EN/FR 11.0