3
Technical data
General data and operating conditions
Ambient conditions
DC mains connection
Max. mains voltage range
E82xV251K2... and E82xV371K2...
E82xV551K2... to E82xV752K2...
E82xV551K4... to E82xV903K4...
Operating conditions
Motor connection
Length of the motor cable
Mechanical
Vibration resistance
2
(9.81 m/s
= 1 g)
Mounting conditions
Mounting place
Mounting position
Dimensions,
free spaces
Weights
102
450 V − 0 % ... 740 V + 0 %
not possible
140 V − 0 % ... 370 V + 0 %
450 V − 0 % ... 775 V + 0 %
450 V − 0 % ... 625 V + 0 %
The DC voltage must be symmetrical to PE.
The controller will be destroyed if the +U
conductor is earthed.
< 50 m
< 100 m
For rated mains voltage and switching frequency £ 8 kHz
without additional output filters.
For compliance with EMC regulations, the permissible cable
length may be different.
Germanischer Lloyd
Amplitude ±1 mm 13.2 ... 100 Hz:
5 ... 13.2 Hz
acceleration resistant up to 0.7 g
IEC/EN 60068−2−6
Amplitude 0.075 mm 57 ... 150 Hz:
10 ... 57 Hz
acceleration resistant up to 1 g
In the control cabinet
Vertical
^
^
"Operation at increased rated power"
l
Chapter "Mechanical installation"
Chapter "Technical data", "Operation at rated power" or
Operation at rated power
Operation at an increased rated
power
conductor or −U
G
shielded
unshielded
EDK82EV113 DE/EN/FR 11.0
G