2
Technical data
Standards and application conditions
Conformity
Approvals
Vibration resistance
Climatic conditions
Permissible
temperature ranges
Permissible installation
height
Mounting positions
Freee space
80
CE
Low−Voltage Directive (73/23/EEC)
UL 508C
Underwriter Laboratories (File−No. E132659)
Power Conversion Equipment
Acceleration resistant up to 2g (Germanischer Lloyd, general conditions)
Class 3K3 to EN 50178 (without condensation, average relative humidity 85
%)
transport
−25 °C ... +70 °C
storage
−25 °C ... +60 °C
operation
−20 °C ... +60 °C
reduce the rated output current by 2.5%/°C above +40 °C
0 ... 4000 m amsl
reduce the rated output current by 5%/1000 m above 1000 m amsl
Any mouning position is possible
above
100 mm
to the
100 mm
sides
EDK82MV222 DE/EN/FR 8.0
L