3
Technical data
3.1
General data/ application conditions
Conformity
Approvals
Max. permissible
motor cable length
1)
(without additional
output filters)
Vibration resistance/vibration
Climatic conditions
Permissible
temperature ranges
Permissible installation height
Mounting positions
Discharge current to PE (to EN 50178)
Type of protection (EN 60529)
Protection measures against
Insulation of control circuits
1)
For compliance with EMC regulations, the permissible cable lengths must be changed.
Stop!
The operation in the DC bus connection is not possible with the drive controllers
EMF8221 ... EMF8227!
L
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
CE
UL 508C
shielded:
50 m
unshielded:
100 m
Acceleration resistance up to 0.7g (Germanic Lloyd, general conditions)
Class 3K3 to EN 50178 (without condensation, average relative humidity 85 %)
Transport
-25 °C...+70 °C
Storage
-25 °C...+60 °C
Operation
-10 °C...+55 °C
0 ... 4000 m amsl
vertical
> 3.5 mA
IP20
Short circuit, earth fault (earth-fault protected during operation, limited earth-fault protection
during power up), overvoltage, motor stalling, motor overtemperature (input for PTC or thermal
2
contact, I
t monitoring)
Safe mains isolation: Double/reinforced insulation to EN 50178
EDK82EV903 DE/EN/FR 2.2
Technical data
Low-Voltage Directive (73/23/EEC)
Underwriter Laboratories (File-No. E132659)
Power Conversion Equipment as of version E82EVxxxKxBxxxXX VA 21
With rated mains voltage and chopper frequency of 8 kHz
reduce the rated output current by 2.5%/°C above +40 °C
reduce the rated output current by 5%/1000 m above 1000 m amsl
65