Installing The Bench Sensor F2 (Optional); Installing The Humidity Sensor Wc4-H-H (Optional); Installing The Humidity/Temperature Sensor Fts2 (Optional) - Sentiotec wave.com4 Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 78
Installation instructions, only for experts
4.7. Installing the humidity/temperature sensor FTS2
(optional)
The humidity/temperature sensor must be installed on the wall of the cabin above
the rear bench seat. A distance of about 15 cm from the ceiling of the cabin must
be maintained. Follow the installation instructions for the sensor.
A wooden housing is optionally available for the humidity/temperature
sensor.

4.8. Installing the bench sensor F2 (optional)

The bench sensor must be installed on the wall of the cabin above the rear bench
seat. A distance of about 15 cm from the ceiling of the cabin must be maintained.
To install the bench sensor, carry out the following steps:
1. Drill through the cabin wall with an 8 mm drill bit.
2. Pull the 2-core bench sensor cable through the hole.
3. Fasten the sensor housing using the wood screws supplied.
4. Guide the 2-core bench sensor cable up to the power unit and fasten it with
cable clips.
5. Check that the bench sensor is firmly fastened.

4.9. Installing the humidity sensor WC4-H-H (optional)

The humidity sensor must be installed in the middle of the side wall furthest from
the heater at a height of around 150 cm (Fig. 3 on page 15).
To install the humidity sensor, carry out the following steps:
1. Drill through the cabin wall with an 8 mm drill bit.
2. Pull the 3-core humidity sensor cable through the hole.
3. Fasten the sensor housing using the wood screws supplied.
4. Guide the 3-core humidity sensor cable up to the power unit and fasten it
with cable clips.
5. Check that the humidity sensor is firmly fastened.
p. 16/38