Instructions for use for the user
9.17. Activating the rolling display
Rolling display means that the temperature and humidity (optional) are shown
alternately in the display
To do this, the controller must be set to FIN or HUM mode.
Press the Mode button
Press the Minus 5 and Plus 6 buttons simultaneously for 3 seconds.
► OFF flashes in the display
Press the Plus 6 button to switch to ON. Confirm your selection using
the Mode button
► The standby indicator lamp
9.18. Setting the post-drying programme
You can set the duration and temperature of the post-drying programme.
The controller must be set to HUM mode for this.
Press the Mode button
Press the Plus
6
► 0 flashes in the display
You can now adjust the temperature value if necessary using the Plus/Minus
buttons (-9 to +9).
Press the Mode button
► The standby
► The set post-drying time for heating and fan flash in the display
(0–120 min; default 15 min)
Select the preferred value using the Minus
Press the Mode button
► The standby
► The set time for post-drying without heating but with fan flashes in the dis-
play
1
(10 second interval)
1
until the light indicator lamp
7
.
7
until the humidity indicator lamp
7
and Minus
5
1
.
7
, timer
8
a
.
7
and timer
8
(0–30 min; default 15 min)
(= default)
1
lights up.
8
buttons simultaneously for 3 seconds.
(= default)
and humidity
3
and Plus
5
indicator lamps light up.
a
lights up.
2
lights up.
3
indicator lamps light up.
buttons.
6
p. 32/38
1