12. Troubleshooting

12.1. Error messages

The sauna controller is equipped with diagnostic software which monitors system
statuses when it is switched on and during operation. As soon as the diagnostic
software identifies an error, the sauna controller switches off the sauna heater.
The operating symbols flash and an error number appears in the display
Switch off the sauna controller using the main switch and rectify the fault before
switching it on again.
The following table describes the possible faults and their causes. If necessary,
quote the error number to your customer service specialist.
Fault
Description
No.
-5
No control unit connected.
No control unit is connected
-10
although at least one was
detected during start-up.
-21
Heater temperature sensor broken.
Heater temperature sensor
-22
short circuit.
-24
Bench temperature sensor broken.
Bench temperature sensor
-25
short circuit.
-26
Humidity sensor broken.
-27
Humidity sensor short circuit.
-30
Thermal fuse defective.
Remedy/cause
No control unit has been
connected, or the contact
is poor.
Check contact to control unit.
Defective temperature sensor
or poor contact.
Defective temperature sensor
or short circuit.
Defective temperature sensor
or poor contact.
Defective temperature sensor
or short circuit.
Defective humidity sensor or
poorly/incorrectly connected.
Defective humidity sensor,
poorly/incorrectly connected or
short circuit.
Defective heater sensor,
poor contact or thermal fuse
not connected.