Two-sensor mode with humidity/temperature sensor (FTS2)
(optional – with expansion board)
In two-sensor mode with humidity/temperature sensor, the sauna controller
displays the temperature measured by the humidity/temperature sensor as the
actual temperature.
In two-sensor mode with humidity/temperature sensor, the evaporator is regulat-
ed according to the humidity level measured in the cabin. The sauna controller
displays the actual humidity (in % relative humidity) in the sauna cabin.
Two-sensor mode with bench sensor (F2)
(optional – with expansion board)
In two-sensor mode with bench sensor, a second temperature sensor (bench
sensor) is installed above the rear sauna bench. The sauna controller displays
the temperature measured by the bench sensor as the actual temperature.
In two-sensor mode with bench sensor, the humidity is timed. Only the setpoint
for the humidity (in % relative humidity) is shown on the sauna controller display.
The actual humidity in the sauna cabin when the humidity is timed depends on
the size of the cabin and the evaporator output, and may differ from the setpoint.
Two-sensor mode with humidity sensor (WC4-H-H)
(optional – with expansion board)
In two-sensor mode with humidity sensor, the sauna controller displays the tem-
perature measured by the heater sensor as the actual temperature. The evap-
orator is regulated according to the humidity measured in the cabin. The sauna
controller displays the actual humidity (in % relative humidity) in the sauna cabin.
Three-sensor mode with bench sensor (F2) and humidity sensor (WC4-H-Hx)
(optional – with expansion board)
In three-sensor mode with bench sensor and humidity sensor, the sauna controller
displays the temperature measured by the bench sensor as the actual temperature.
In three-sensor mode, the evaporator is regulated according to the humidity
measured in the cabin. The sauna controller displays the actual humidity (in %
relative humidity) in the sauna cabin.