Installation instructions, only for experts
4.3.

Installing bench sensor F2 (optional)

The bench sensor must be installed on the wall of the sauna room, above the
rear bench seat. An interval of approx. 15 cm to the roof of the sauna room must
be maintained.
To install the bench sensor, perform the following steps:
1. Lay the two 2-pin bench sensor wires in the wall of the sauna room, leading
them to the bench sensor installation location and affi x the bench sensor
wires using wire clips.
2. Pull the two half-shells of the bench sensor apart.
3. Connect the two connectors for the bench sensor wire to the two middle
terminals on the connection panel.
4. Place the connection panel crossways in the bench sensor half-shells.
5. Place the two half-shells together and screw them together using the two
Phillips-head screws (9 mm).
6. Check whether the bench sensor has been securely closed.
7. Install the bench sensor on the wall of the sauna room using the two wood
screws enclosed (16 mm). Maintain an interval of 15 cm to the roof of the
sauna room.
4.4.

Installing the foil sensor (optional)

If one of the following infrared heat plates is connected to an additional output,
the foil sensor P-ISX-FF must be used:
● IR-WP-100
● IR-WP-175
● IR-WP-390
● IR-WP-510
● When installing the foil sensor, observe the operating instructions for the
infrared heat plates.
● Use of a foil sensor must be activated in the technician menu
(see 8.2. Settings in the technician menu on page 26).
WORLD OF WELLNESS
● IR-WPHL-100
● IR-WPHL-175
● IR-WPHL-390
● IR-WPHL-510
p. 15/48