Selection Of Running Time; Selection Of Fan A; Troubleshooting; E1 - Damage To The Safety Temperature Limiter - Sentiotec IS1 Instructions De Montage Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30

11.9 Selection of running time 9

The desired running time can be set here. The setting is made with the 3 and 5 buttons. As long as the target
temperature is displayed, the indicator fl ashes 6. You can now confi rm the set value with 4 or wait until the
value is automatically adopted after 5 seconds.
Tip: The maximum running time is limited by the heating time limitation. See also Point 7.
Running time
<99 min
99 min – 9.9 hrs
> 9.9 hrs

11.10 Selection of fan A

The desired running time can be set here. The setting is made with the 3 and 5 buttons. Either press button 4
or wait 5 seconds until the value is automatically saved to confi rm the setting.
12

Troubleshooting

12.1 E1 - Damage to the safety temperature limiter

The sensor contained in the scope of supply has no safety temperature limiter. Verify the correct fi t of the wire
bridge installed at the factory.

12.2 E2 - Cabin sensor - interruption

Check the cable for damage and the terminals for correct fi t.
12.3 E3 - Cabin sensor – short circuiting
Verify the cable of the cabin sensor for damage.

12.4 E4 - Film sensor - interruption

If you are not using fi lms or hotplates, the dummy sensor installed at the factory (Fig. 5; terminals b -b) must
remain in position.
If you are using a fi lm sensor, check the cable for damage and the terminals for correct fi t.
12.5 E5 - Film sensors - short circuiting
If you are using a fi lm sensor, check the cable for damage and the terminals for correct fi t.

12.6 E6 - Film excess temperature error

If you are not using a fi lm sensor, check the dummy sensor installed at the factory for correct fi t.
If you are using a fi lm sensor, check the cables of the fi lm sensor for damage and the terminals for correct fi t.
If the errors are not rectifi ed by means of the aforementioned measures,
contact your dealer. Do not continue to use the device under any circumstances.
WE DO IT FIRST.
Instructions for use for the user
Setting accuracy
1 min
0.1 hrs (6mins)
1 hr
P. 12/14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Is2P-is2-t

Table des Matières