Installation instructions, only for experts
4.3. Installing the safety shut-off
1. Guide the silicone cable through the respective hole in the cabin wall.
2. Hang the safety shut-off onto the two half-round wood screws that were
screwed into the cabin wall.
3. Check that the rocker is firmly seated and that it can move sufficiently, while
ensuring that stones do not block the rocker.
4. Screw a half-round wood screw into the lower mounting tab
shut-off to fix it in place (Fig. 4 Installing the safety shut-off on page 10)
5. Connection and testing
● Installation may only be performed by a qualified electrician or similarly quali-
fied person.
● The electrical wiring may only be laid when the power has been disconnected.
5.1. Sauna control units with connection terminals for safety
shut-offs
(e.g. Pro-B2, Pro-B3, Pro-C2, Pro-C3, JUST-105D-CO, JUST-105W-CO,
JUST-105D-FI, JUST-105W-FI)
● Guide the red silicone cable to the sauna control unit and connect the two
wires to the terminals labelled "OSG".
5.2. Sauna control units without connection terminals for safety
shut-offs
(e.g. WC4-B-L, O-CV31, O-CK31, etc.)
● Observe Fig. 5 Connection on page 13 and the operating instructions for
your sauna control unit.
If your sauna does not feature control terminals for a safety shut-off device, you
must integrate the safety shut-off into the circuit for the excess temperature fuse
of the heater sensor (F1).
WORLD OF WELLNESS
p. 11/16
of the safety
2
EN