Sun SWB 340 Notice D'utilisation page 122

Table des Matières

Publicité

Troubleshooting
H0
Wheel silent running cannot be improved with
optimisation.
H1
Further optimisation is not recommended but is
possible.
H2
Weight minimisation is recommended, further
optimisation does not bring improvements.
H22
Pedal unclamping is disabled.
The machine is equipped with a clamping device
fi tted with a tie rod on the chuck (e.g. USV or SCA);
unintentional unclamping could damage the tie rod.
H26
The gauge was moved too quickly.
Return the gauge at the starting position and repeat
the operation, making the gauge approach the weight
application point more slowly.
H28
The gauge was moved too slowly.
Return the gauge the starting position and repeat
the operation, bringing the gauge towards the weight
application point again.
H33
The SONAR does not work.
H80
Recalibration was not set up. As a result, it cannot be
performed by the operator.
Press the STOP key to clear the message.
Call the service team for machine calibration.
H82
Fault during self-test (e.g.: by turning the wheel).
The message is displayed for 3 seconds, then the
measurement must be repeated (max. 10 times) or
aborted by pressing the STOP key.
122