Commissioning
4.4

Lifting the inhibit in the case of an error

The most frequent causes of the triggering of the inhibit state are:
 alignment errors between sensor and actuating element
 damage to the connecting cable between sensor and evaluation
unit
 insufficient approach speed (cf. chapter 1.4.3 "Minimum approach
speed and response range")
 failure to observe the delay time set
 Rectify error.
 Open protective device and close again.
 Perform test as described in chapter 4.1 "Tests before the first
commissioning".