5
Technical specifications
Tab. 1: Technical data
RE 4000
74
© SICK AG • Industrial Safety Systems • Germany • All rights reserved
Technical specifications
5.1
Evaluation unit
Control category to EN 954-1
PDF class in compliance with
EN 60947-5-3
Housing material
Enclosure rating in compliance
with IEC 60529
Weight
Protection class
Operating temp.
Outputs
Number of sensors
Tightening torque
for the connection terminals
Mechanical life
Usage category
Max. switching current/switching
voltage
Max. switching capacity
Min. switching current/switching
voltage
Short-circuit protection
1)
Use of the delayed release output 57/58 up to cat. 3.
Operating Instructions
1)
Up to cat. 4
PDF-S
Polycarbonate
IP 20
675 g
As per EN 50178 and EN 61140
–10 °C ... +55 °C
3 safety-relevant output signal
switching devices (N/O contact)
13/14, 23/24 and 33/34
1 signal output (N/C contact)
41/42
1 delayed release safety-relevant
output signal switching device
57/58 (can be set from
0.6−30 s)
Min 2, max 6
1 Nm
6
1 × 10
switching operations
AC-15 240 V 2 A
DC-13 24 V 1 A
AC: 4 A/250 V AC at COS Φ = 1
DC: 2 A/30 V DC
1000 VA at COS Φ = 1
10 mA/10 V AC/DC
AC: 5 A fast blow;
DC: 3 A fast blow