α ≤ 120°
The two weights must be placed within an arc of
120°, including the Pe weight.
To start this programme, proceed as indicated
below:
-
Select one of the balancing programmes, ALU1
or ALU2.
-
Perform a spin.
-
At the end of the spin, if there is an unbalance
on the outer side (Pe), the machine will display
the Hidden Weight button
the main screen.
-
Press this button;
-
The machine performs a full-speed low speed
wheel during which, by means of the front
laser triangulator, recognizes the number of
spokes in the rim;
-
At the end of the video procedure, an image
of the imbalance appears with two position
indicators for the external side. The unbal-
ance value displayed for this side refers to
the indicator in the centered position.
The application of each of the two balancing
weights is carried out as described in the
paragraph "Application of balancing weights".
If the operator wants to change the position
of the imbalances automatically calculated
by the machine, it is possible to perform the
procedure in MANUAL mode by pressing the
button
CAUTION:
EYELIGHT Plus DiagnosticLine - Operator's manual
17
on
again
If the machine in automatic mode is not able
to recognize the rims of the rim, the program
is predefined manually at the end of the cycle.
the internal laser pointer will automatically
move onto the outer plane (Pe).
-
Turn the wheel clockwise until you reach the
point where you want to apply the first outer
weight (P1) and align the laser point with a
spoke.
-
press the button
on the monitor to confirm the operation;
-
Turn the wheel anticlockwise until you reach
the point where you want to apply the second
outer weight (P2) and align the laser point
with the second spoke.
-
press the button
on the monitor to confirm the operation;
-
When the procedure is completed, the unbal-
ance image is displayed on the screen includ-
ing two position indicators for the outer side.
The unbalance value displayed for this side
refers to the indicator in the centred position
condition.
Each of the two balancing weights is applied as
described in the "Balancing weight application"
section.
CAUTION:
If the machine in automatic mode is not able
to recognize the rims of the rim, the program
is predefined manually at the end of the cycle.
You can quit the Hidden weight procedure at
any time by simply pressing the Exit button
.
The Hidden weight function can be disabled by
pressing the Hidden Weight.
UTILITY AND
CONFIGURATION
PROGRAMMES
The Utility programmes are all the functions of
the machine that are useful for its operation but
are not strictly connected to its normal operation.
or the button
or the button
UK
65