19. automatic weight selection (AUTOWS):
-
configures automatic selection of balancing
programme in relation to the characteristics
of the rim (ALU1, ALU1 programme enabled
- ALU2, ALU2 programme enabled - OFF,
disabled)
20. enables/disables rim search:
-
if enabled, the machine recognises auto-
matically, during the spin with dimension
acquisition, if a complete wheel is present or
only the rim (YES active – NO deactivated).
21. 3D scanning speed
-
used to change the wheel (or only rim) spin
speed while performing a 3D scanning pro-
gramme (range from 30rpm to 70rpm).
22. 3D scanning motor step
-
used to change the motor steps while perfor-
ming a 3D scanning programme between one
position and the next (range from 1 to 5).
23. Opening / closing emergency system C (wheel
locking device)
- to enable the opening / closing system emer-
gency C to suit your needs (SI active - NO off)
- When the program is running you can open and
close, the device C in case of failure of the
control pedal C (M, Figure 10) or the device
WINUT. Press the key
opening and closing of the automatic locking
device C present in the screen working.
24. Advantage weight
It is possible to select the width of the adhe-
sive weight used to balance the wheels from
a minimum of 15mm to a maximum of 40mm.
25 cycle time
It is possible to change the launch cycle time,
namely:
-
STANDARD factory setting
-
FAST reduced cycle time of about 2 seconds
from the factory setting.
26. tyre diagnosis
It is possible to modify the tire diagnosis,
namely:
-
NORMAL to scan on a larger surface of the tire
-
FAST factory setting where scanning is faster.
EYELIGHT Plus DiagnosticLine - Operator's manual
27. Set factory data:
-
to reset the initial machine configuration
Machine calibrations are not modified.
To save the new settings, press the Save
6.3. Unbalance sensitivity calibration
This procedure should be performed whenever
calibration appears to be out of the tolerance
range or when the machine requires this pro-
cedure to be performed by displaying the E 1
error message.
Calibrate as follows:
-
select the sensitivity calibration icon in the
configuration programme menu;
-
Fit a wheel of average dimensions (diameter
no less than 14") and preferably with a small
imbalance only on the wheel balancer.
-
-
At the end of the spin, fix the calibration
weight supplied with the machine on the
shaft assembly bell as indicated in figure 20.
to perform the
-
perform a second spin;
-
At the end of the spin, change the position of
the calibration weight on the shaft assembly
bell as indicated in figure 21
button and press the Exit button
to go back to the main working screen.
perform a spin;
UK
20
75