Removal

DANGER
Danger due to fluids hazardous to health!
If the pump is used in fluids hazardous to health, de-
contaminate the pump after dismantling and before
carrying out any other work! There is a risk of fatal in-
jury! Observe the specifications in the work regula-
tions! The operator must make sure that the person-
nel have received and read the work regulations!
DANGER
Risk of death due to electrocution!
Improper conduct when carrying out electrical work
can lead to death due to electric shock! Electrical
work must be carried out by a qualified electrician in
accordance with the locally applicable regulations.
DANGER
Risk of fatal injury due to dangerous lone
working practices!
Work in chambers and narrow rooms as well as work
involving risk of falling are dangerous work. Such
work may not be carried out autonomously! A second
person must be present for safety reasons.
WARNING
Risk of burns from hot surfaces!
Motor housing can become hot during operation. It
may cause burns. Allow the pump to cool down at
ambient temperature after switching it off!
NOTICE
Use only properly functioning lifting equip-
ment!
Use only properly functioning lifting equipment to lift
and lower the pump. Ensure that the pump does not
become jammed during lifting and lowering. Do not
exceed the maximum bearing capacity of the lifting
equipment! Check that lifting equipment is function-
ing properly before use!
8.4.1
Stationary wet well installation
Pump is decommissioned.
Gate valves on the inlet and pressure side closed.
1. Disconnect the pump from the mains.
Installation and operating instructions Wilo-Rexa CUT GI
Shut-down/dismantling
8.4.2
8.4.3
2. Attach the lifting equipment to the attachment point.
CAUTION! Never pull on the power supply cable! This
damages the power supply cable!
3. Slowly raise the pump and lift above the guide pipes
from the operating space. CAUTION! The power supply
cable can be damaged while lifting! Hold the power
supply cable slightly taut when lifting!
4. Clean the pump thoroughly (see point "Cleaning and dis-
infecting"). DANGER! Disinfect the pump when used in
fluids hazardous to health!
Portable wet well installation
Pump is taken out of operation.
1. Disconnect the pump from the mains.
2. Roll up the power supply cable and place it over the mo-
tor housing. CAUTION! Never pull on the power supply
cable! This damages the power supply cable!
3. Loosen the pressure pipe from the pressure port.
4. Attach the lifting equipment to the attachment point.
5. Lift the pump from the operating space. CAUTION! The
power supply cable may be squeezed and damaged
when setting the pump down! Pay attention to the
power supply cable when setting the pump down!
6. Clean the pump thoroughly (see point "Cleaning and dis-
infecting"). DANGER! Disinfect the pump when used in
fluids hazardous to health!
Clean and disinfect
DANGER
Danger due to fluids hazardous to health!
Danger to life if the pump is used in fluids hazardous
to health! Decontaminate the pump before carrying
out any further work! Wear the following protective
equipment while performing cleaning tasks:
• Closed safety goggles
• Breathing mask
• Protective gloves
⇒ The equipment listed here is the minimum re-
quirement, observe the specifications of the
work regulations! The operator must make sure
that the personnel have received and read the
work regulations!
Pump is dismantled.
Contaminated cleaning water is disposed of in the sewer
in accordance with local regulations.