S
ERIAL COMMUNICATION
6.1

RS232 communication port

Calys60/80/120 serie has a standard RS232 serial port for communicating with a
PC.
Connect the serial cable to the calys mini-din connector on the left side as in the
figure below:
WARNING:
CONNECT THE RS232 PORT IN SAFE AREA ONLY
Manuel d'intructions NTA47248-300A4
6.2
To change the baud rate on the instrument, press the [MENU] key.
MENU
MENU
Co n f i g u r a t i o n
Co n f i g u r a t i o n
Un i t
Un i t
Ra mp - Me mo r y s c a n
Ra mp - Me mo r y s c a n
Da t a l o g g e r
Da t a l o g g e r
Ad v a n c e d
Ad v a n c e d
Pr e s s < > t o SET
Pr e s s < > t o SET
Press the [ ] and [ ] keys to highlight the required baud rate value.
Press the [ ] key to select the option. Press the [ESC] key to return in
measure mode without changes.
6.3
The instrument has embedded in its memory a software (firmware) which is loaded at
every turning on and which allows operating. This firmware can be changed and
substituted; this guarantees a continuous upgrade of the instrument and the
exploitation of its possibilities.
To upgrade the firmware, you need the ST167Flash program and a file with
extension "HFW", which represents the firmware itself that has to be transferred to
the instrument.
This software is compatible with all versions of Windows. The program needs the
following minimum requirements of the Personal Computer:
Pentium CPU with at least 16MB of RAM
20MB free space on hard-disc
Monitor with resolution 800x600
Microsoft mouse or compatible
To install the program, follow the procedure:
Insert the CD-ROM
From "Start" menu, select "Run..."
Insert the filename "D:Setup.exe" (eventually, substitute the letter "D" with the
proper ID of your CD-ROM drive)
Follow the instructions showed on the screen by the installation program
98

Baud Rate setting

Co n f i g u r a t i o n
Co n f i g u r a t i o n
Di s p l a y
Di s p l a y
Po we r On [ Se t
Po we r On [ Se t
Ch ]
Ch ]
Da t e / t i me
Da t e / t i me
Re j e c t i o n [ 5 0 Hz ]
Re j e c t i o n [ 5 0 Hz ]
Ba u d r a t e [ 9 6 0 0 ]
Ba u d r a t e [ 9 6 0 0 ]
Pr e s s < > t o SET
Pr e s s < > t o SET

Firmware upgrade: STFlash

MENU
MENU
9 6 0 0
9 6 0 0
1 9 2 0 0
1 9 2 0 0
3 8 4 0 0
3 8 4 0 0
5 7 6 0 0
5 7 6 0 0
1 1 5 2 0 0
1 1 5 2 0 0
Pr e s s < > t o SET