Getting Started; Unpacking; Charge The Battery; Power Up - AOIP calys 60 IS Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
G
ETTING STARTED
4.1

Unpacking

Remove the instrument from its packing case and remove any shipping ties, clamps,
or packing materials.
Carefully follow any instructions given on any attached tags.
Inspect the instrument for scratches, dents, damage to case corner etc. that may
have occurred during shipment.
If any mechanical damage is noted, report the damage to the shipping carrier and
then notify AOIP SAS directly or its nearest agent, and retain the damaged
packaging for inspection.
A label indicates the model and the serial number of the instrument. Refer to this
number for any inquiry for service, spare parts supply or application and technical
support requirements. AOIP sas will keep a database with all information regarding
your instrument.
4.2

Charge the battery

Before you use the calibrator for the first time, charge the battery pack for 8/10 hours
by connecting the external battery charger.
WARNING
FOR THE IS MODELS USE THE EXTERNAL BATTERY CHARGER IN SAFE
ZONE ONLY
4.3

Power up

Press the [ON/OFF] key to switch the instrument on and off. The instrument needs
some seconds to check the hardware and to run the autocalibration procedure.
4.4

Automatic channel protections

The unit is protected against over-voltage and over-current inputs, by firmware and
by thermal fuses.
The thermal fuses do not need replacement when activated. They automatically
restore the input channels after some minutes.
Manuel d'intructions NTA47248-300A4
The firmware is designed to load the last instrument settings.
WHEN THERMAL FUSES ACTIVATE, YOU SHOULD DISCONNECT THE
ELECTRICAL CONNECTIONS FROM THE UNIT AND SWITCH THE
INSTRUMENT OFF FOR ABOUT 2 MINUTES. THE THERMAL FUSES WILL BE
AUTOMATICALLY RESTORED AND YOU CAN RESUME YOUR WORK.
4.5
Before you use the calibrator for the first time, adjust the current data and time of the
unit.
Switch the instrument ON by pressing the [ON/OFF] key.
Press the [MENU] key.
MENU
MENU
Co n f i g u r a t i on
Co n f i g u r a t i on
Un i t
Un i t
Ra mp - Me mo r y s c a n
Ra mp - Me mo r y s c a n
Da t a l o g g e r
Da t a l o g g e r
Ad v a n c e d
Ad v a n c e d
Pr e s s < > t o SET
Pr e s s < > t o SET
Press the [ ] and [ ] keys to highlight the "Date" option. Press the [ ] key to
set the system date.
Press the [ ] and [ ] keys to highlight the parameter to set. Press the [ ]
key to modify the value.
75

IMPORTANT

Date and time setting

MENU
MENU
Di s p l a y
Di s p l a y
Po we r i n [ Set
Po we r i n [ Set
Ch ]
Ch ]
Da t e / Ti me
Da t e / Ti me
Re j e c t i o n [ 50 Hz ]
Re j e c t i o n [ 50 Hz ]
Ba u d r a t e [ 9 6 0 0 ]
Ba u d r a t e [ 9 6 0 0 ]
Pr e s s < > t o SET
Pr e s s < > t o SET
Da t e
DD [ 0 1 ]
MM [ 0 8 ]
YY [ 0 3 ]
Fo r ma t
[ Eu r o ]
Pr e s s < > t o SET
Da t e / Ti me
Da t e / Ti me
Da t e
Da t e
Ti me
Ti me
Pr e s s < > t o SET
Pr e s s < > t o SET

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Calys 80 isCalys 120 isCalys 80 p isCalys 80 pCalys 60 pCalys 60 p is

Table des Matières